Every wafer met spec; the furnace run decided where it landed
Does the oxide furnace hold 560 ± 100 Å, and what moves the thickness? A semiconductor fab grows a thin oxide film on silicon wafers in a furnace, and the case study sets the goal at 560 Å, give or take 100. Each row is one wafer: 21 furnace runs, four zones in the furnace, two wafers per zone. Every wafer passed. The spread inside the window comes mostly from run to run, not from where a wafer sat in the furnace.
Interactive chart available when JavaScript loads.
Every wafer sits inside the window, with room to spare
The bins are 10 Å wide and start at the lower limit, so the plot spans the whole specification and nothing else. The dashed lines are the limits; the tinted space past them is empty. 100.0% of the 168 wafers fell inside 460 to 660 Å. The thinnest wafer measured 487 Å and the thickest 634 Å, so the closest call was 26 Å from the upper limit. The median wafer measured 562.5 Å, close to the 560 Å target.
Interactive chart available when JavaScript loads.
Runs move the thickness more than zones do
Each column of points is one furnace run, colored by zone. Within a run the four zones land close together, but whole runs shift up or down. Run 3 averaged 517.1 Å and run 7 averaged 594.4 Å, a gap of 77 Å between two runs of the same process.
Interactive chart available when JavaScript loads.
The four zones have nearly the same center
Pooled over all 21 runs, the zones barely differ. Zone 1 averaged 561.4 Å and Zone 2 averaged 566.6 Å, about 5 Å apart, while the runs above span 77 Å. Zone 3 has the widest range, because it holds both the thinnest and the thickest wafer.
Interactive chart available when JavaScript loads.
Takeaway
The furnace met its specification on every wafer, so a pass rate says nothing more here. To center the process tighter, the place to look is what changes between runs, not the layout of the zones.
Limits
This is one study of 168 wafers from 21 runs, with no dates or run conditions, so it cannot say why runs differ. The ± 100 Å window is the goal stated in the case study, not a customer specification. Two wafers per zone is a small sample for comparing zones within one run.